Sign in

Terence Luk

@simtiva.app
449 followers 278 following 63 posts

Terence Luk, Anaesthetist, Creator of SimTIVA.app - free & open source TCI/TIVA simulator - progressive web app #ansky

PostsRepliesMedia
Terence Luk @simtiva.app · 10/02/2026
Introducing CloudTimer.app Have you conducted a viva or osce examination? My friend Eric and I wrote this app to help synchronize the countdown timer - this web app is a cloud-connected timer, so that the host can control a timer session and multiple viewers can connect to it simultaneously.
Front screen of cloudtimer.app
242
Terence Luk @simtiva.app · 05/12/2025
December updates - Simtiva.app: (1) Infusulator, a retrospective data entry tool to simulate the infusion data from time series of CP/CE target values. (2) Live preview for manual mode. The graph will be plotted as you type in the bolus or infusion values so you can preview the change in real time
200
Terence Luk @simtiva.app · 04/12/2025
Upcoming feature: live preview of bolus/infusion rate change in manual mode. Sometimes, we need to change our inf rate or give an extra bolus, SimTIVA now plots the curve for the predicted changes dynamically as you enter your values. Video demo of "live preview" of reducing inf rate from 50 to 30
111
Terence Luk @simtiva.app · 21/11/2025
"Infusulator", first created by Matthew Hart, coming soon to SimTIVA. It allows easy entry of a time series of CE (or CP) targets to generate TCI simulations. The conversion from CET/CPT to dosage (volume infused, or the total dose) over time is made simple. An export module is also provided.
231
Reposted by Terence Luk
Anaesthesia @anaesjournal.bsky.social · 01/10/2025
Total intravenous anaesthesia (TIVA) for rapid sequence induction (RSI) Worried your TIVA infusion is too slow for RSI? Why not work with your local manufacturer to develop an ‘RSI-TCI’ mode for your target-controlled infusion pumps? #AnSky #PharmSky doi.org/10.1111/anae...
151
Reposted by Terence Luk
Anaesthesia @anaesjournal.bsky.social · 01/10/2025
"... a ‘RSI–TCI’ mode with a pre-programmed manual bolus offers a pragmatic solution for those who wish to preserve an intact pharmacokinetic model for accurate propofol delivery, while allowing the rapid induction clinicians expect from a manual bolus." #AnSky #MedSky doi.org/10.1111/anae...
0105
Terence Luk @simtiva.app · 20/09/2025
Today I have updated simtiva.app and simtiva.vet - The changes are mainly visual, with a refreshed look. Part of the reason is user feedback regarding the new iOS 26 on iPhones partially breaking the user interface with malpositioned top and bottom elements. Minor bugfixes as well. #ansky
000
Terence Luk @simtiva.app · 04/09/2025
Ketamine (Kamp) model will be improved soon. On Simtiva, the Kamp model used a ke0 of 0.238, from Navarette PD study using ANI index (ref1). However, that PD study applies to the Domino PK set, and ke0 is model-specific and should not be naively applied to another PK model... (1/4) #ansky
Kamp model for ketamine using different ke0's
100
Terence Luk @simtiva.app · 27/08/2025
jaj42.github.io/blog/posts/2... An excellent and interesting read for those interested in TCI and programming! STANPUMP is an amazing piece of software
jaj42.github.io
Deep dive into STANPUMP – blog
010
Terence Luk @simtiva.app · 06/07/2025
Low-dose ketamine infusion is an excellent component of multi-modal opioid-sparing analgesia. Kamp model uses meta-analytical technique to facilitate better plasma site targeting for TCI ketamine. This model is now introduced in SimTIVA.app pubmed.ncbi.nlm.nih.gov/32997732/ (1/2) #ansky
simtiva.app
SimTIVA | Free TIVA Simulation App to Simulate Target-Controlled Infusion | Simple TCI Calculator
Simple and free TIVA simulator
161
Terence Luk @simtiva.app · 30/06/2025
journals.lww.com/co-anesthesi...
journals.lww.com
The future of target-controlled infusion and new... : Current Opinion in Anesthesiology
il, and dexmedetomidine, suitable for use in a wide variety of patients, but still not universally applicable. A validation study of the predictive performance of the Eleveld propofol model showed rea...
010
Terence Luk @simtiva.app · 28/06/2025
Renewed interest in Ketamine emerged as a result of potentially new indications. Kamp model is an allometric model based on meta-analytical analysis. journals.lww.com/anesthesiolo... Coming soon to simtiva.app #ansky
040
Terence Luk @simtiva.app · 12/06/2025
Happy to share that Simtiva (veterinary version), a TIVA simulator for small animals, was successfully used to guide TIVA in prolonged surgery in a cat, and the results were recently published in VAA journal. Simtiva.vet was co-developed by Enzo Minghella & me 1 yr ago and is actively updated.
020
Terence Luk @simtiva.app · 02/05/2025
SimTIVA.app is fully capable of offline support. The app can be run offline. Internet connection can be unstable sometimes, but rest assured you can still run SimTIVA normally. Also, minor changes to the mcg/kg/min default rate unit display (manual mode) for Propofol, the bug is fixed. #ansky
030
Reposted by Terence Luk
GasGasGas - The FRCA Primary Exam Podcast @gasgasgaspodcast.bsky.social · 25/04/2025
You've been meaning to get around to reading about the differences between adult TCI models for propofol? On the to do list for .... ever?? Listen to this to get you warmed up, and check out the references in the show notes for the in depth excitement you're desperate to have! #ansky #FOAMed
gasgasgas.uk
TIVA Models for Propofol
TIVA Models for Propofol delivery in anaesthesia. Comparing their pharmacokinetics, clinical use, and pitfalls for the FRCA exam and beyond.
364
Terence Luk @simtiva.app · 22/04/2025
Minor update to Simtiva.app: propofol concentration options available: 10mg/ml, 20mg/ml, or custom dilution; plus other bug fixes
000
Terence Luk @simtiva.app · 17/04/2025
Feature preview: propofol concentration can be customized (10mg/ml, 20mg/ml, or custom dilution)
Propofol concentration customizationPropofol concentration customization
000
Reposted by Terence Luk
Nicholas Chrimes @chrimesy.com · 11/04/2025
The term "TIVA RSI" misrepresents the issue. All RSIs are IV. Whether it's a TIVA anaesthetic depends on whether the subseq maintenance agent is inhaled or IV (& irrelevant to the process of RSI). The question is whether IV induction agents should be administered by an infusion pump during RSI.
3105
Reposted by Terence Luk
Anaesthesia @anaesjournal.bsky.social · 10/04/2025
Do you use TIVA when you are doing a rapid sequence induction in theatre? #AnSky #AirwaySky #MedSky doi.org/10.1111/anae...
151
Reposted by Terence Luk
Anaesthesia @anaesjournal.bsky.social · 10/04/2025
What is your preferred methodology for in-theatre TIVA RSI? #AnSky #AirwaySky #MedSky doi.org/10.1111/anae...
021
Terence Luk @simtiva.app · 07/04/2025
Simtiva.app update: RSI mode to facilitate guidance of TIVA in an RSI situation. Eleveld model. #AnSky
000
Terence Luk @simtiva.app · 07/04/2025
Simtiva.app update: Dexmedetomidine (Hannivoort) model. CET/CPT/Manual mode available. Welcome any feedback
000
Terence Luk @simtiva.app · 04/04/2025
Feature preview: RSI mode coming soon to simtiva.app! How do you do RSI with TIVA? The algorithm suggests a bolus dose based on user-defined CE target at a specified time point (e.g. 60s). It also predicts a CE overshoot & when to resume infusion. Also testing live preview feature... #ansky
021
Terence Luk @simtiva.app · 04/04/2025
Feature preview: testing dexmedetomidine TCI on simtiva.app - coming soon #ansky
dexmedetomidine TCI
011
Terence Luk @simtiva.app · 21/03/2025
Upcoming feature: y-axis (concentration) can be adjusted. User can define the max. concentration on graph display instead of relying on automatic algorithm
000
Terence Luk @simtiva.app · 21/03/2025
Out of the 6500+ simulations performed with simtiva.app in the past 3 months, Eleveld model was the most popular model, accounting for over half of the sessions performed. Schnider and Marsh models were 2nd and 3rd most used models.
000
Reposted by Terence Luk
Patient Safety Learning @patientsafetylearning.org · 18/03/2025
🆕The @who.int has announced that the theme of World Patient Safety Day 2025 will be “Safe care for every newborn and every child”, emphasising the need for stronger measures to protect children from preventable harm. Read more below⬇️ www.pslhub.org/learn/organi... #patientsafety
pslhub.org
World Patient Safety Day 2025
This year’s World Patient Safety Day on 17 September is focused on the theme “Safe care for every newborn and every child”. This article explains the aims of the event and the areas it will cover.
097
Terence Luk @simtiva.app · 18/12/2024
At work, with SimTIVA 😁
Simtiva Fullscreen mode
010
Terence Luk @simtiva.app · 14/12/2024
2024 Recap (4) Do you prefer to use Schnider or Marsh model in TCI? SimTIVA.app has an “Eleveld emulation tool” that converts a Marsh/Schnider TCI infusion scheme into CP, CE & estimated BIS values as predicted by the Eleveld model. This helps to compare older models with the Eleveld model. #ansky
SimTIVA Eleveld emulation tool
040
Terence Luk @simtiva.app · 14/12/2024
2024 Recap (3) In March, I have increased the max infusion duration to 6h (previously 2h). This should be adequate for most cases. A warning prompt will appear to suggest the user to continue with usage of SimTIVA. Once a new target is updated, you can run the sim for another six hours.
Warning prompt 6 hours max limit reached
000
Terence Luk @simtiva.app · 14/12/2024
2024 Recap (2) Time travel: SimTIVA is designed to be run in real-time, in parallel to the time course of an actual clinical case. In addition, SimTIVA also allows you to jump back and forth in time, like skipping to different time points of a video; resetting to time zero; or pause a sim.
Time control panel
000
Terence Luk @simtiva.app · 14/12/2024
2024 Recap (1) SimTIVA.app has introduced a number of features this year. In Jan, we have added a “preview box” to describe the upcoming infusion scheme as you input a new Target, so you can can adjust your pump settings in advance
SimTIVA preview box
000
Terence Luk @simtiva.app · 07/12/2024
Of all the nerdy things that I do, I find much joy in troubleshooting the “arrow” problem: the arrow of the trend line of the PTOL index was always a bit off… but why? I finally fixed it
Probability of tolerance to laryngoscopy index trend on SimTIVA.app
110
Reposted by Terence Luk
Dr Paramdeep Jandu @psjandu.bsky.social · 30/11/2024
Enjoying the eBIS on @simtiva.app and how it’s comparing to real time values! My Braun pump doesn’t give that number
111
Reposted by Terence Luk
Balazs @cannulaservice.hibalazs.net · 29/11/2024
My entry for the @sivatrainees.bsky.social #SIVA24 infographic competition. Is there one model to rule them all? Well tbh I think it doesn't matter all that much, as long as you know your model well! You can find a more detailed explanation on my website: hibalazs.net/anaesthesia/... #ansky
6209
Reposted by Terence Luk
JAMA @jama.com · 28/11/2024
RCT: Perioperative intravenous lidocaine infusion did not improve the return of gut function after elective minimally invasive colonic resection. ja.ma/4eNDNi7
1166
Terence Luk @simtiva.app · 25/11/2024
Working over the weekend to clean up and optimize the code, most of the changes are under the hood, this won't add new features but will minimize the load times and initial file size transferred. As a web app, performance and speed matter. Load times consistently around 1s across the globe.
010
Terence Luk @simtiva.app · 21/11/2024
Simtiva.app TIP: ✨ U may share your simulation via the "share" button (A). U may then choose to share the sim as a picture (B) or a weblink (C) via your favorite apps. U may enter a filename(D). Weblinks can be opened by the SimTIVA viewer which has an interactive interface. manual.simtiva.app?ch=9
100
Terence Luk @simtiva.app · 20/11/2024
Hi, also introducing: Simtiva.vet is a web app developed by me and Enzo Minghella. It helps to guide total intravenous anaesthesia (TIVA) in small animals. The models included are Beths (Propofol), Cattai (Propofol), Cattai (Fentanyl) in dogs and Cattai (Propofol) in cats. #vetsky #vetmed
010
Terence Luk @simtiva.app · 14/11/2024
First post here! Simtiva.app is a web-based simulator for TCI/TIVA. It allows the use of Eleveld model (the latest one!) for propofol in "CE targeting", so you may use the suggested scheme on any syringe pump without TCI Eleveld functionality. Other drugs and models also available for simulation...
42312