seumasm.bsky.social @seumasm.bsky.social · 09/12/2025Not a bad choice, mirrors the partnership with VW group and Nissan with the Micra. I haven't been in a 5, a colleague got a A290 GTS (first in Scotland back in July from Aberdeen). Definitely more comfortable than the Zoe, quieter road noise, felt a bit skittish with FWD when his foot was down. 030
seumasm.bsky.social @seumasm.bsky.social · 09/12/2025eu-evs.com/bestSellers/... It is currently leading for the quarter, due to a strong October, Model Y and 3 beat it for November, it is number 2 for December but Model Y is strong and suspect it will take the quarter, even including Alpine numbers, Renault 5 could be second, which is impressive.eu-evs.comElectric Vehicle registrations in Europe: 15 countries, majority of BEV market 120
seumasm.bsky.social @seumasm.bsky.social · 12/02/2025Regarding Visit a heat pump in Outer Hebrides, I registered mine last month, no interest so far, it appears to the first one. Home Energy Scotland recommend the Energy Saving Trust - Greener Homes Network (2 properties). app.visitaheatpump.com/hosts/723 greenhomesnetwork.energysavingtrust.org.ukapp.visitaheatpump.comSemi-detached property, hosted by James | Visit a heat pump 120
seumasm.bsky.social @seumasm.bsky.social · 12/02/2025I'm also sceptical, some background to this is a surplus of hydrogen on Orkney due to test facilities, they also have some extremely short routes so if it might work anywhere this might be it. They are also considering hybrid-electric/electric only options. www.emec.org.uk/facilities/h...emec.org.uk Hydrogen R&D facilities : EMEC: European Marine Energy Centre 110
seumasm.bsky.social @seumasm.bsky.social · 10/02/2025Renault #HydrogenSoufflé commercial vehicle edition. Incredibly predictable, at least some realism seems to be being expressed at CEO level from a major auto manufacturer now, shame the funds weren't invested in their EV platforms. www.hydrogeninsight.com/transport/th... @mliebreich.bsky.socialhydrogeninsight.com'There is currently no market for hydrogen vehicles', admits Renault CEO after joint-venture collapseThe French auto firm’s Hyvia joint venture with Plug Power has been in receivership since December 171
seumasm.bsky.social @seumasm.bsky.social · 09/02/2025Thanks, I have Home Assistant setup in the house already, you can control the Zappi from HA? You recommend Solar Edge? Considering it with Powerwall 3, I'll be limited to G98/3.68kW, looking at 10 panels roof mount (~4.2kWp). Impressed with the Powerwall 2 and 9*430W JA solar panel & Solis 3.6kW. 000
seumasm.bsky.social @seumasm.bsky.social · 09/02/2025Was considering getting a Zappi in a house with a Powerwall 2 and solar (Solis inverter), do you recommend it? Was wondering if/how they integrate? Use an Ohme ePod on another property with no solar or battery currently, like the lack of mobile network reliance with the Zappi and solar support. 000
seumasm.bsky.social @seumasm.bsky.social · 09/02/2025Pretty good for a base rate, the advantages (lack of dependence on gas) and disadvantages (relative lack of flexibility) of French nuclear. Only a few days my average rate has been below that this Winter. Suspect the French fleet will be doing a lot of export this year with the elevated gas prices. 110
seumasm.bsky.social @seumasm.bsky.social · 08/02/2025Yes, above is for my mother's house, also switched my own house over to Go from Cosy for the EV. I also hope to get solar/battery in there this spring. I suspect high gas prices will persist making Agile/Tracker less attractive. ~10kWh solar + overnight battery charge provides enough for heatpump 010
seumasm.bsky.social @seumasm.bsky.social · 08/02/2025Shifted tariff to Octopus Go (8.5p/kWh 0000-0530, 26.87p/kWh otherwise). Heatpump running mostly on cheap rate&solar, reduced total grid demand ~21kWh, daily costs ~£5. ~4p/kWh heat, cheap running costs. Combination of PV/battery/tariff/heatpump is impressive. Average ~3.63kWh solar/day (22 days). 251
seumasm.bsky.social @seumasm.bsky.social · 08/02/2025It is possible to install the Powerwall 2 under a G98, that is the case here. It seems more suitable to DNO restrictions than say the GivEnergy AIO. The Powerwall 3 is DC coupled. I don't like the politics myself but I still believe in the company although this install wasn't my decision. 110
seumasm.bsky.social @seumasm.bsky.social · 06/02/2025Looks like they sell for ~£32k with 140k miles on them from Autotrader with warranty. Spoke with one of drivers up in Edinburgh at a rapid he had it for 4 years done a lot of mileage and some long distance, very happy with it. Think they were £60k new and he used Scot Gov assistance to purchase. 030
seumasm.bsky.social @seumasm.bsky.social · 04/02/2025Moving it to Self-Powered in the afternoon after DHW cycle then it doesn't need to be on Time-Based Control till cheaper 2200 slot. It is only aware of the heat pump load and the electric shower, these are irregular in demand. It is aggressive about charging to 100% unlike their EV 80% approach. 100
seumasm.bsky.social @seumasm.bsky.social · 04/02/2025I'm impressed with the Tesla Powerwall's algorithm. It is a little frustrating to have such little automated control of it in the Tesla App but using the Netzero app (www.netzero.energy) you can tell it to switch between Self-Powered and Time-Based Control (uses time of use tariff data given to it).netzero.energyNetzero 110
seumasm.bsky.social @seumasm.bsky.social · 04/02/2025I think people will be very surprised how quickly (on a decadal scale) this will take place, even EVs are very inefficient (in a financial sense) depreciating assets. 110
seumasm.bsky.social @seumasm.bsky.social · 04/02/2025@duncanlamont2.bsky.social I think you have an impersonator duncan-lamont .bsky.social (without the space), he follows your followers and reaches out in DMs (presumably to scam) reported account. 110
seumasm.bsky.social @seumasm.bsky.social · 03/02/2025I drive a Renault Zoe ZE50 if I was to choose again now second hand I would probably go Kia e-Niro/Hyundai Kona 64 kWh with heat pump, MG5 or older Tesla Model 3. The older Ioniq 38 kWh with shorter range and BMW i3 is also a good choice. ev-database.org is a good resource.ev-database.orgEV DatabaseA complete overview of all electric vehicles in Europe. Search and compare by range, make, model and price. 000
seumasm.bsky.social @seumasm.bsky.social · 28/01/2025Ecodan 6kW R290, 1970s semi 2 bedroom, loft insulation, unfilled cavity, new radiators, Octopus Cosy tariff. Replaced sparingly used resistive/storage heaters was reliant on solid fuel stove last winter. Overall average electricity use similar to last winter, no coal now, improved thermal comfort. 030
seumasm.bsky.social @seumasm.bsky.social · 26/01/2025Solar production over 9 and a bit days is 26.15 kWh, averaging > than 2.6 kWh for 3.87 kWp system in mid to late January at 58.47N, production more than covers heat pump demand in Octopus Cosy peak period (via Powerwall) & approximately almost 10% of overall household demand during the same period. 240
seumasm.bsky.social @seumasm.bsky.social · 23/01/2025Haven't got it in the North West of Scotland, ~140 miles NW of the Red area. Forecasting gust of 90 mph+ but less impact here I guess. Never had a red warning up here? Or at least since these alerts have been active. 210
seumasm.bsky.social @seumasm.bsky.social · 23/01/2025Help to have new panels I guess, they are bifacial if that adds much, I'm pleasantly surprised they produce in dull conditions. Will be frustrated by clipping from the inverter by Spring I expect, should have tried for more panels for current period. Hopefully they'll stay in place with the wind. 010
seumasm.bsky.social @seumasm.bsky.social · 23/01/2025Interesting, I misspelt/got my units mixed up. I meant kWp which will be the 2.87 figure (7 panels?). That seems like pretty decent production, the PV-GIS calculation I did was only for ~50+kWh January, ~30+kWh December for the system I mentioned above. 010
seumasm.bsky.social @seumasm.bsky.social · 23/01/2025Neat feature of the Tesla Powerwall 2 is Storm Watch grid charging, even without the DNO approval in place it grid charges (not normally possible) when Storm Watch is active. Period is 0600-2359 tomorrow. DGAF about peak rate, £2 for ~5 hours potential off grid heating feels worth it. 020
seumasm.bsky.social @seumasm.bsky.social · 23/01/2025What is the DC kWhp rating of your panels? I've been impressed by average 2.4 kWh/day on a 3.87 kWhp system for mid-late Jan over 6 days, ~150 miles North of you. Early days, 9 x JA Solar 430 W panels and a 3.6 kW Solis inverter. Angled to South-SouthWest no obstructions, relatively flat terrain. 110
seumasm.bsky.social @seumasm.bsky.social · 23/01/2025Yes, the ECO actually seemed less efficient but I don't really trust the reported COPs on Ecodans much. My mother's system is trending to 2.1 (Heating & DHW). 2.6 - Heating 1.6 - DHW My own R290 6kW unit is 3.2 combined. 3.3 - Heating 2.7 - DHW Consumption reported on the R290 is 30%+ measured. 020
seumasm.bsky.social @seumasm.bsky.social · 23/01/2025Yes, I have an R290 (FTC7) Ecodan 6kW myself and it underpredicts 30%+ on average on energy used vs a Shelly clamp, I presume the production numbers are similarly inaccurate. The estimated usage on the 8.5 kW R32 Ecodan FTC6 seems far closer. I think lack of pump measurement is a large factor. 000
seumasm.bsky.social @seumasm.bsky.social · 22/01/2025I had similar reservations, it was designed for 45 degree flow, the radiators are decently sized. We paid for 4 extra. Two are mostly switched off. Arguably we haven't had an extended design temperature test, the coastal location keeps temperatures significantly milder than elsewhere. 010
seumasm.bsky.social @seumasm.bsky.social · 22/01/2025The thermostat is generally set to 19 C on AutoAdapt it rarely falls below that, I placed the thermostat in the bedroom to give better elder occupant comfort than in hallway, I increment temp sometimes to spur it into action. Using I would say in the high teens of kWh daily on average since install. 120
seumasm.bsky.social @seumasm.bsky.social · 22/01/2025insulation (to be completed) it is delivered through a government scheme in Scotland aimed at over 75 year old occupants with no existing 'central heating' this replaced storage heaters, which had also been installed via a government scheme in mid 2000s. The installer considered the 11.2 kW unit ... 210
seumasm.bsky.social @seumasm.bsky.social · 22/01/2025It is my mother's house, they built it mid 1980s, what was called a 'kit' house, timber frame block exterior. Relatively poorly insulated, as it had a peat burning Rayburn range stove. Four bedrooms, ~140 sqm. This was to be delivered as part of a larger package of works, including underfloor ... 110
seumasm.bsky.social @seumasm.bsky.social · 22/01/2025Peaked at 376 gCO2/kWh, think that might be a recent record? Highest average as well in the short period I've been monitoring it. I wonder if the dip was gas generation going offline during low demand? Also not often I expect you see solar outperforming wind at this time of year. 010
seumasm.bsky.social @seumasm.bsky.social · 20/01/2025Heat pump installed 40 days ago, running well during briefly sub zero weather. Powerwall 2 installed last week along with solar (~3.6 kWhp). Solar generation covering all Cosy peak tariff (4pm-7pm) heat pump use in January (@58.47° North) since operational, admittedly mostly mild temperatures so far 140
seumasm.bsky.social @seumasm.bsky.social · 20/01/2025A lot of that carbon intensity is for supplying South Scotland and marginally 'North West England' and 'North Wales and Merseyside' (via subsea link through South Scotland). Doesn't change the fundamentals though, my mother got a Powerwall fitted last week so no heat pump load during peak period. 010
seumasm.bsky.social @seumasm.bsky.social · 20/01/2025You were looking at the Scots wikipedia page for the car. sco.wikipedia.org/wiki/Daihats...sco.wikipedia.orgDaihatsu Materia - Wikipedia 010
seumasm.bsky.social @seumasm.bsky.social · 16/01/2025Recommend Octopus Compare app on Android and iOS, small monthly charge of ~50p if you want beyond the last month comparison. If you are tariff swapping you need to track the change of tariff dates elsewhere, there is also a Beta function for Consumption Shift. Upcoming rates also included. 020
seumasm.bsky.social @seumasm.bsky.social · 16/01/2025My experience with a 6kW R290 is that the Ecodan over predicts power usage on average by 37% vs a Shelly 1M with a high degree of variability. The tariff trials seems to be capped to a small number of users and a total number of kWh per user. It seems like a good idea but uses unreliable data. 010
seumasm.bsky.social @seumasm.bsky.social · 14/01/2025Propane is the refrigerant used, it is not consumed it may eventually leak and need to be topped up but it is not the fuel or burnt, my small domestic unit has 0.6 kg propane (6 kW/20k BTU). It has orders of magnitude less GWP than the other commonly used refrigerants (R32, R410a, R134a). 020
seumasm.bsky.social @seumasm.bsky.social · 07/01/2025Mitsubishi Ecodan's have Coastal Protection models (indicated by model codes ending in BS) widely used in the 'coastal' islands of Scotland without issue over 10+ years they are manufactured in central Scotland. It historically was an issue. library.mitsubishielectric.co.uk/pdf/book/Eco...library.mitsubishielectric.co.ukEcodan Coastal Protection Models (BS) Product Information Sheet - Document Library - Mitsubishi Electric 000
seumasm.bsky.social @seumasm.bsky.social · 06/01/2025Largest period of 0 intensity recently was 14th-26th Dec - 12 days 3.5 hours, with other multi days periods since Oct The Carbon intensity calculation methodology won't be perfect and there maybe some bugs in how it is picked up in the integration but it is an interesting data to play around with. 000
seumasm.bsky.social @seumasm.bsky.social · 06/01/2025Plot and csv data linked below. gist.github.com/seumasmorris... October 1st to today gist.github.com/seumasmorris... Home Assistant - Integration github.com/BottlecapDav... 100
seumasm.bsky.social @seumasm.bsky.social · 06/01/2025I found it interesting roughly matching the data for North Scotland in the Octopus Energy integration in Home Assistant with my heat pump demand averaged 15 gCO2e/kWh previously. The last changed value of 0 sometimes sticks around for 10 days or so! 110
seumasm.bsky.social @seumasm.bsky.social · 21/12/20248.5 kW R32 Ecodan installed 12/12/2024. Replacing resistive heat, mainly mild outside temps. Average flow temperature ~35C. Ecodan reported COP 2.63 (163kWh in, 429kWh out). Massive improvement in thermal comfort, house demand costs probably closer to 40% with Cosy, ~£7.3/day last 5 days. 250
seumasm.bsky.social @seumasm.bsky.social · 17/12/2024I think the link in the show notes should be. www.edinburgh-heating.co.uk/contactedinburgh-heating.co.ukContact Us Edinburgh Heating Always Quality Work Edinburgh Cookie ControlEdinburgh Heating | Heating Engineer Edinburgh the Lothians - Always quality work 110
seumasm.bsky.social @seumasm.bsky.social · 10/12/2024Seems to have been deployed in Glasgow, I wonder if a similar solution could be used for looped supplies or existing constrained developments. www.eon.com/en/innovatio... youtu.be/rLbZDy-q9pUyoutu.beThe future of grid is dynamiX • Energy Tech SummitYouTube video by Futurae Events 000
seumasm.bsky.social @seumasm.bsky.social · 07/12/2024Interesting, what model do you have? My own one is slightly oversized (or perhaps rightly sized). I have only seen it do a few defrosts during heating, I think the Ecodans tend to defrost more frequently so the issue is they spend insufficient time heating. 100
seumasm.bsky.social @seumasm.bsky.social · 07/12/2024I think heat pump design should (and with MCS needs to?) be treated as the sole source of heat. It has been designed to 45C flow temp @ design temp (~-3C locally?) after underfloor improvement. Hoping for a mild winter prior to underfloor work community.openenergymonitor.org/search?q=%22...community.openenergymonitor.orgSearch results for '"death spiral" order:latest' - OpenEnergyMonitor CommunityOpen-source tools for energy monitoring and analysis 100
seumasm.bsky.social @seumasm.bsky.social · 07/12/2024I agree, an 8.5kW has been specified, based on 7kW heat loss after underfloor insulation is installed. The system will be under sized until underfloor is done. Existing resistive heaters will supplement a little, solid fuel stove will be installed. Hopefully avoiding defrost death spiral. 100
seumasm.bsky.social @seumasm.bsky.social · 05/12/2024If you retrofit a heat meter, do you have to drain the whole radiator loop? 100