Sign in

Spectrometrics Limited

@spectrometrix.bsky.social
474 followers 3K following 176 posts

The Chemistry of Collaboration™ 🇬🇧 🇮🇪 your Boutique Consultant and Analytical Solutions Partner for Great Britain & Ireland. Solutions for analytical chemistry. Instruments, solutions, analysers, software, spectral libraries & more spectrometrics.com

PostsRepliesMedia
Spectrometrics Limited @spectrometrix.bsky.social · 24/09/2026
Also in GxP environments venting the system can be usually written into the SOP for trained users - unplugging cables/byassing usually requires higher level authority (or management through change control).
000
Spectrometrics Limited @spectrometrix.bsky.social · 24/09/2026
Does the same job, just automates it (with millisecond switch over). Many UK labs don’t have easy access to bypass the pump. Longer term aiming to add more capabilities - control through CDS and active vacuum management.
100
Spectrometrics Limited @spectrometrix.bsky.social · 24/09/2026
It vents your MSD to backing vacuum, with wear on your Turbo pump equivalent to a couple of hours continuous operation (most of the wear on a full vent cycle comes from pumping air and water). On a Monday morning, you can be fully operational in just over 2 hours!
100
Spectrometrics Limited @spectrometrix.bsky.social · 24/09/2026
We’ve just taken delivery of our first MSLoVent™ for testing. The MSLoVent™ saves 30% on power and carrier gas costs for your GC-MSD/similar instruments that can be shut down over the weekend (more for infrequently used instruments) with minimal unplanned downtime risk! enquiries@spectrometrics.com
Agilent 8890/5977C GC-MSD - vanilla coloured rectangular laboratory instruments with autosampler and LCD display
100
Spectrometrics Limited @spectrometrix.bsky.social · 29/08/2026
Many thanks to @biswamisra.bsky.social for bringing this product to Spectrometrics attention.
010
Spectrometrics Limited @spectrometrix.bsky.social · 29/08/2026
Based in Europe and doing #Breathomics, studying eCigarettes/vaping, oral malodour or oral care products? If so the #VolaTrap is a great device for breath sampling into TD tubes and we’re launching it at #BMSS2026 Leeds next month! @bmss-official.bsky.social #BMSS46
VolaTrap sampling device for sampling exhaled breath onto TD tubes
100
Spectrometrics Limited @spectrometrix.bsky.social · 21/08/2026
Attending @bmss-official.bsky.social next month. European launches for two #MassSpec products at ATG Scientific Booth.
SFC-EI-MS systemIMR-MS (SIFT-MS) System
001
Spectrometrics Limited @spectrometrix.bsky.social · 28/07/2026
For everyday lab equipment like GCs and HPLCs should you really have to spend a fortune (that’s better spent on people) on the hardware or consumables to get a quality solution? enquiries@spectrometrics.com
Gas chromatograph with PAL3 RTC sampler
010
Spectrometrics Limited @spectrometrix.bsky.social · 17/07/2026
If you do #AnalyticalChemistry, the right water purifier can pay for itself - but you need to trust that whoever specced the system in your lab got right model and filters for your analytical techniques (IC, HPLC, GC, TOC, bio-chromatography). enquiries@spectrometrics.com
010
Spectrometrics Limited @spectrometrix.bsky.social · 12/07/2026
Finally, a factory built, mobile monitoring lab with extended mass range SIFT-MS plus GPS and 4G for real-time monitoring and 3D mapping of atmospheric and airborne pollution. @ncas-uk.bsky.social @nickmolden.bsky.social
Infographic describing the benefits (remote, onsite and GPS spatial mapping of pollution) of mobile air monitoring lab Image of 3.5t mobile laboratory van white with black tinted rear windows
110
Spectrometrics Limited @spectrometrix.bsky.social · 12/07/2026
IMR-MS: Echoing the Chemistry of Life’s Origins IMR-MS (Ion Molecule Reaction Mass Spectrometry) uses the same ultra-soft ionisation chemistry that forges the prebiotic building blocks of life in deep space’s molecular clouds! #TeamMassSpec - the small molecule #MassSpec missing from your lab! 🌌🧪
Pillars of creation image from Hubble Space telescope depicting elephant trunks of interstellar gas and dust in the Eagle Nebula of the Serpens constellation, some 6,500–7,000 light-years (2,000–2,100 pc) from Earth. Orange hued pillars of clouds in a blue hazy background dotted with magenta stars
000
Spectrometrics Limited @spectrometrix.bsky.social · 26/06/2026
Attending #EnvChem2026 next week? Find @nathhawkins.bsky.social at the ATG Scientific booth to learn about: • Sustainable sample prep • capillary/μPacked SFC • New to the UK SIFT-MS • GC-FTIR for environmental forensics and emerging contaminants ID #SIFTMS #IMRMS
Selected Ion Flow Mass Spectrometry (SIFT-MS) instrument
100
Spectrometrics Limited @spectrometrix.bsky.social · 19/06/2026
#TeamMassSpec - did you know you can improve the mass and spectral accuracy of your HRAM instruments (and for #Orbitrap systems mitigate AGC loss isotopic fidelity) with an affordable software upgrade! enquiries@spectrometrics.com #Geochemistry #Metabolomics #MSImaging
static.klipy.com
Pressing Update Button
Alt: Pressing Update Button
010
Spectrometrics Limited @spectrometrix.bsky.social · 18/06/2026
Seeking SIFT-MS in the UK & Ireland (plus most of the EU) - new product launch soon! enquiries@spectrometrics.com
SIFT-MS instrument
000
Spectrometrics Limited @spectrometrix.bsky.social · 11/06/2026
Did you know that the OPTIC-5 Inlet can be installed with LN2, LCO2 or cryo-refocusing allowing a wide range of injection techniques (including Hot Injection & Trapping for Headspace and SPME). With a PAL3 Sampler and LINEX, you can automate Thermal Desorption too! enquiries@spectrometrics.com
OPTIC-5 model technical comparison of models (MultiPurpose Inlet, Thermal Desorber, Pyrolyzer
000
Spectrometrics Limited @spectrometrix.bsky.social · 10/06/2026
What if you could get the same quality #Chromatography consumables (vials, caps, autosampler syringes) without the price premium of main market vendors… enquiries@spectrometrics.com
static.klipy.com
Hwang Jun Ho: How Much Are We Talking?
Alt: Hwang Jun Ho: How Much Are We Talking?
000
Spectrometrics Limited @spectrometrix.bsky.social · 27/05/2026
So cool, our engineering partners can now 3D print in PEEK!
static.klipy.com
George Clooney: Lurk Peek
Alt: George Clooney: Peeking out over turf from below a sand dune
000
Spectrometrics Limited @spectrometrix.bsky.social · 07/05/2026
Doing your protein crash for HPLC in a microfuge tube? Did you know you can do it in the autosampler vial and inject from the supernatant to cut your single-use plastic waste enquiries@spectrometrics.com
Vial micro-centrifuge for 8 x 2mL autosampler vials. Great box with blue LCD display panel
000
Spectrometrics Limited @spectrometrix.bsky.social · 18/04/2026
#TeamMassSpec NIST26 is set to be the biggest change since NIST98 - a revolutionary rather evolutionary upgrade for both GC-MS and LC-MS enquiries@spectrometrics.com
Flyer for NIST26 full GC/MA chromatogram analysis by NIST EI Library
042
Spectrometrics Limited @spectrometrix.bsky.social · 01/04/2026
*or Europe
000
Spectrometrics Limited @spectrometrix.bsky.social · 01/04/2026
Upgrading your GC-MS? If anyone in the UK has an Agilent 5973N (or higher) MSD with Performance Turbo EI (or CI) they’d be willing to donate to a University instrument development research project, we’d love to hear from you. enquiries@Spectrometrics.com
media.tenor.com
a cartoon of two people shaking hands against a purple background
Alt: a cartoon of two frogs shaking hands against a purple background captioned collaboration
101
Spectrometrics Limited @spectrometrix.bsky.social · 28/03/2026
If the situation in the Gulf drags on, helium prices will go up. If you’re doing GC or GC-MS and can’t switch to hydrogen, adding a universal helium conservation module can save you a a small fortune. The Ecosaver from Spectrometrics works with virtually any GC/GC-MS! enquiries@spectrometrics.com
Multicoloured Helium Balloons on the ceiling of a room with white walls and ceiling.
000
Spectrometrics Limited @spectrometrix.bsky.social · 28/03/2026
Is your lab short on electrical outlets. Spectrometrics has a range of add-ons that typically let you pull the plug on at least two outlets per #MassSpec system.
000
Spectrometrics Limited @spectrometrix.bsky.social · 28/03/2026
Thermal Desorption and dynamic headspace are a great tool for the R&D lab, but for a QC or routine lab you really need something that is robust, rugged and easy to use. Spectrometrics do TD and DHS options that work with virtually any GC/GC-MS. enquiries@spectrometrics.com #Volatilomics, #VOCs
GERSTEL DynamicHeadspace Option for Multi Purpose Sampler
000
Spectrometrics Limited @spectrometrix.bsky.social · 16/03/2026
Recently I found an interesting paper on Extended Simulated Distillation by Capillary SFC. A more sustainable (lower power consumption, helium-free) alternative to GC-FID/GC-MS with Selerity Technologies commercially available, off-the-shelf instruments for #petrochem enquiries@spectrometrics.com
ogst.ifpenergiesnouvelles.fr
Extended Simulated Distillation by Capillary Supercritical Fluid Chromatography | Oil & Gas Science and Technology - Revue d'IFP Energies nouvelles
Oil & Gas Science and Technology - Revue d'IFP Energies nouvelles
001
Spectrometrics Limited @spectrometrix.bsky.social · 10/03/2026
If you have an analytical problem, if no one else can help, and if you can find us....maybe you should speak to Spectrometrics enquiries@spectrometrics.com
media.tenor.com
a man wearing a green shirt and a cowboy hat
Alt: Templeton Peck (Dirk Benedict, The A-Team), putting his hat on and turning his head towards camera and glancing
000
Spectrometrics Limited @spectrometrix.bsky.social · 18/02/2026
Thermal desorption, thermal extraction and pyrolysis with ambient ionisation MS? Applications include seized drug analysis, the direct analysis of chemical warfare agents and explosives in complex environmental matrices, polymer analysis, flavour/aroma release. enquiries@spectrometrics.com
Cover of Analytical Pyrolysis Techniques and Applications textbook
000
Reposted by Spectrometrics Limited
Nathan Hawkins @nathhawkins.bsky.social · 09/02/2026
As part of our committment to sustainability, @spectrometrix.bsky.social sends consumables out in reused boxes. In this case, the contents are possibly not as exciting as the picture on the box!
Box from an elephant gift mobile phone holder
011
Spectrometrics Limited @spectrometrix.bsky.social · 08/02/2026
Available with 3/8 or KF16 adapter
Micro oil mist filters (blue plastic cylinder containing white filter element). One fitted with 3/8 threaded adapter, other with KF16 adapter
000
Spectrometrics Limited @spectrometrix.bsky.social · 08/02/2026
Available with 3/8 or KF16 adapter
Micro oil mist filters (blue plastic cylinder containing white filter element). One fitted with 3/8 threaded adapter, other with KF16 adapter
000
Spectrometrics Limited @spectrometrix.bsky.social · 06/02/2026
#TeamMassSpec! Your E2M1.5/Duo 2.5 pump hates having a blocked oil mist filter. It makes your pump feel lousy, run a fever, and the back pressure damages its seals. Fix: Spectrometrics value pack: a year's supply: cheaper than one of these Agilent originals enquiries@spectrometrics.com #MassSpec
Agilent oil mist filter for Duo 2.5 rotary pump (blue plastic casing with a white filter element)
211
Spectrometrics Limited @spectrometrix.bsky.social · 03/02/2026
#TeamMassSpec - we’re working on our 2nd Generation MSSoftVent™ that could deliver up to 80% savings on your backing pump electricity consumption and running costs. enquiries@spectrometrics.com #MassSpec #Sustainability #Science
media.tenor.com
a man in a red shirt and black gloves is standing in front of a door
Alt: Scotty (James Doohan) a red shirt and black heavy duty rubber gloves throwing an arcing electricity switch.
000
Spectrometrics Limited @spectrometrix.bsky.social · 25/01/2026
Phthalates are one of the most common contaminants in GC analysis. Loose bagged vial caps are a major source. Spectrometrics are your one-stop stop for affordable vials, caps and autosampler syringes. With a range of phthalate, PFAS and siloxane free cap options.
Magnetic screw caps for 2mL short thread autosampler vials
021
Spectrometrics Limited @spectrometrix.bsky.social · 25/11/2025
Do you want to cut consumable waste by 2 tonnes/yr per assay? Spin GC and HPLC vials from 2 mL to 40 mL directly – no transfers, no culture/microtubes, straight to autosampler. ROI <6 months for routine labs. UK-made, IP-protected swing-out buckets (23/28 mm). enquiries@spectrometrics.com
Vial centrifuge for 10/20mL headspace vials showing rotor with swing-out buckets and bowl.
010
Spectrometrics Limited @spectrometrix.bsky.social · 18/11/2025
🥼 Spectrometrics solutions are ideal for mid-range UKRI capital equipment initiatives like BBSRC Alert. Analysis for Innovative research that works from biomarker discovery through large scale nutrition & health studies. Add a unique, national capability to your lab! enquiries@spectrometrics.com
Selerity supercritical fluids chromatography SFC-MS system (available in μpacked and capillary configurations)
010
Spectrometrics Limited @spectrometrix.bsky.social · 22/10/2025
This month saw the end of Windows 10, but if you’re one of the labs with a 5973N MSD stuck in a Windows 7 time warp, now is the right time to invest in a backup Windows 7 PC as an insurance policy before compatible PCs all end up in the scrap heap in the sky.
media.tenor.com
a man pointing at the camera with the words " back to the future " behind him
Alt: Doc Brown man pointing at the camera with the words " back to the future " behind him as Marty McFly stands up to look what he’s pointing at
010
Spectrometrics Limited @spectrometrix.bsky.social · 16/10/2025
We designed the MSSoftVent™ for SFC-EI-MS where we routinely shut the instrument down after a sequence has finished.
Capillary supercritical fluids chromatography-mass spectrometry (SFC-MS) system comprising SFC (cream & blue box shaped instrument) and Agilent 5977 MSD (cream and charcoal grey box)
010
Spectrometrics Limited @spectrometrix.bsky.social · 13/10/2025
#TeamMassSpec: we’ve developed the MSSoftVent that lets you shut down your #MassSpec to save energy, but keep it under backing vacuum for rapid start up. enquiries@spectrometrics.com Though it’s been designed for Agilent GC-MSD/QQQ systems, it will work on many other systems.
Cut away schematic of turbomolecular pump showing rotor blades, shaft and bearings
140
Spectrometrics Limited @spectrometrix.bsky.social · 02/10/2025
🥰 For Sale: Refurbished PAL-xt sampler seeking a new GC-MS soulmate! Fully serviced, ready to inject love into your lab. Reliable, precise, & full of charm. email: enquiries@spectrometrics.com for details! 💖 #LabEquipment #GCMS #ScienceLove
GERSTEL branded PAL-xt sampler configured for headspace and liquid injection
010
Spectrometrics Limited @spectrometrix.bsky.social · 18/09/2025
If you want to upgrade to a PAL3, we do these too - and ours aren’t locked to the vendor!
000
Spectrometrics Limited @spectrometrix.bsky.social · 18/09/2025
🇬🇧 🇮🇪- Do you have a vintage PAL or GERSTEL MPS? Did You can upgrade to a certified pre-owned PAL-xt (single or dual head) for a fraction of the cost of a new PAL3, and to keep the costs down further, you can reuse your existing objects. enquiries@spectrometrics.com
PAL Classic autosampler (ribbed body) configured for headspace and liquid injection
110
Spectrometrics Limited @spectrometrix.bsky.social · 06/09/2025
The calibration/QC standard savings are actually higher because new standards only have to be brought into use half as often.
000
Spectrometrics Limited @spectrometrix.bsky.social · 06/09/2025
It’s essentially a straight scale down without a full revalidation. For MCERTS or GxP, there are potentially further savings in electricity use, up to 10x improvements in detection limits and delivery of higher sample throughput that could be delivered through change control or an NS30 validation.
000
Spectrometrics Limited @spectrometrix.bsky.social · 06/09/2025
Just done a desk study for a lab doing VOC analysis. Spectrometrics technology can let them scale down to 10 mL vials saving TWO tonnes of waste glass per GC-MS system per year, HALVE their costs on calibration and QC standards, and save 10% on vial costs (£2000/yr). enquiries@spectrometrics.com
media.tenor.com
kermit the frog is standing in front of a red curtain with the words supergreen written on it .
Alt: kermit the frog is standing in front of a red curtain with the words supergreen written on it .
210
Spectrometrics Limited @spectrometrix.bsky.social · 29/08/2025
Splitless headspace analysis is a game changer for labs doing residual solvents, environmental & biogenic VOCs. It also opens up Hot Injection & Trapping (HIT) with a standard Agilent inlet (for headspace, SPME, SPME arrow and related techniques).
SPME multi fibre exchange module for PAL3 sampler
010
Spectrometrics Limited @spectrometrix.bsky.social · 22/08/2025
Did you know you can upgrade your existing Agilent MSD to a triple quad for a fraction of the price of a 7000E. You can even upgrade a diff pump system! enquiries@spectrometrics.com #sustainability #greenchemistry
Agilent 5977A MSD with Evolution QQQ upgrade
010
Spectrometrics Limited @spectrometrix.bsky.social · 15/08/2025
Calling #TeamMetabolomics UK - Spectrometrics has 3 #Metabolomics PrepStations in stock to automate the Fiehn MOX-TMS Protocol. Great for teaching metabolomics or for early career researchers wanting to automate GC-MS metabolomics. @scotmetnet.bsky.social @emn-metsoc.bsky.social @lbmsdg.bsky.social
021
Spectrometrics Limited @spectrometrix.bsky.social · 04/08/2025
Zivak’s Multitasker takes control of the data analysis in CE-IVD workflows, saving you the cost of a CE-IVD LC-MS. This means that in many countries, you can use the standard (research) version of your #MassSpec. Get the Robot + MassSpec for less than the CE-IVD LC-MS!
Zivak multitasker robot for clinical and forensic toxicology assays
030
Spectrometrics Limited @spectrometrix.bsky.social · 31/07/2025
We supply the hardware/software/firmware - you need to supply/source the #woofware
000
Spectrometrics Limited @spectrometrix.bsky.social · 29/07/2025
And it’s not just GC-MS and LC-MS: Just-in-time (or offline PrepAhead for consistent post-prep hold-times) can also be done for NMR (best with short, 100mm tubes). Bruker (and less expensive 3rd parties) do options for high-field and benchtop instruments.
000