Sign in

Lewis Bowick

@l-bow.bsky.social
130 followers 100 following 411 posts

Engineering and economics of the energy transition. Electrification of heat, renewables, energy networks and various other pieces of the jigsaw.

PostsRepliesMedia
Lewis Bowick @l-bow.bsky.social · 26/07/2025
A secondary frustration with the "solar makes HPs make sense" concept is that upfront cost is HPs' greatest challenge IMO. To mainstream this for ordinary households, the last thing we need is to say "you just need to drop a further £8k for it to be worthwhile"
010
Lewis Bowick @l-bow.bsky.social · 26/07/2025
What's screwey is that fixed cost are recovered via the energy consumption charge. As a result, electrifying makes you overcontribute to fixed costs, while generation lets you undercontribute. The two cancel each other out, causing the illusion that micro solar complements heat electrification.
230
Lewis Bowick @l-bow.bsky.social · 26/07/2025
The idea that micro generation, costing 2-3x as much as grid-scale generation, with a generation profile inversely correlated to the heating season, makes electric heating more economic than using the grid should tell you something's screwey with the price signals
120
Lewis Bowick @l-bow.bsky.social · 26/07/2025
I'm pretty sure it does more harm than good. Only one third of the retail price of electricity is for energy, so the "true" saving of rooftop PV must be about 8p/kWh of self consumption. The other two thirds are just shifted to everyone else's bills, making electrification even less appealing.
110
Lewis Bowick @l-bow.bsky.social · 25/07/2025
Ooft. Hadn't thought it might get that bad
100
Lewis Bowick @l-bow.bsky.social · 24/07/2025
Because of politics?
100
Lewis Bowick @l-bow.bsky.social · 24/07/2025
The whole reason for CP30 was, I think, that in 2022 it looked like any additional renewable capacity would bring down bills. Now that wholesale has come down and CfDs have risen, I'm not sure there's any merit to a 2030 sprint (besides being the right direction of travel for carbon overall)
120
Lewis Bowick @l-bow.bsky.social · 13/07/2025
District cooling is a thing, though I'm not convinced that would be easier than an individual building approach, given the need for co-ordination across many building owners and civil works. It would still need fan coils to be installed indoors. New build is an ideal opportunity for A2A I'd say
011
Lewis Bowick @l-bow.bsky.social · 13/07/2025
Efficiency of air-to-water is very sensitive to the water temperature required by the radiators. If you've got underfloor heating or very big radiators then great, but if not you can get COPs much worse than you would with warm air. I think retrofitting refrigerant pipes more likely!
010
Lewis Bowick @l-bow.bsky.social · 13/07/2025
Yep air-to-water is the default path for our homes. Just seems like a shame to be rolling out heat-only systems right when we realise we're gonna need AC. If we could combine the cooling perk with decarbonisation it would be a much easier transition.
130
Lewis Bowick @l-bow.bsky.social · 13/07/2025
UK here, been trying to figure out if mini-splits could work for us at scale. The trouble is we all have whole house hydronic systems, so would need to double up with splits in every room. And how do you deal with bathrooms? More likely is people just put splits in bedrooms and keep using gas heat
100
Lewis Bowick @l-bow.bsky.social · 13/07/2025
I was recently talking to Christoph at goeconic.com who are offering this setup
goeconic.com
Econic Energy | Heat Pumps | Save Money & Emissions | England
Econic's mission is to build the next wave of energy transition in the UK: the decarbonisation of heating. We are committed to making your transitioin to a green future affordable, easy, and bespoke t...
010
Lewis Bowick @l-bow.bsky.social · 13/07/2025
You can have fan coils connected to the pipework as well as radiators, which can provide effective cooling with proper moisture removal. The pipework needs to be insulated to avoid condensation. Probably quite hard to find installers who will do it atm
321
Lewis Bowick @l-bow.bsky.social · 07/07/2025
True, heat pumps will only introduce about 30% as much additional heat to the environment as other forms of heating. So no cooling, but a reduced contribution to urban heat island in winter
100
Lewis Bowick @l-bow.bsky.social · 07/07/2025
I'd be interested to know if these studies have taken into account that the portion of heat being blown onto the street which has been removed from the building is being cancelled out by that building absorbing heat through its leaks. Only the portion covered from electricity is a net addition.
000
Lewis Bowick @l-bow.bsky.social · 07/07/2025
In both heating and cooling mode, heat is moved between indoors and out, plus heat is generated by electricity being burnt off as friction. So in both cases there's a net addition of heat. The hot air blown out is a combination of the heat moved from indoors and the heat added from electricity.
100
Lewis Bowick @l-bow.bsky.social · 06/07/2025
Heating just adds heat to a building at the same rate it escapes to outdoors. It's an equilibrium to maintain a steady temperature, so there's no net removal of heat from the environment.
220
Lewis Bowick @l-bow.bsky.social · 30/06/2025
Raises the question of whether we should be insulating pipes at installation to make them cooling-ready
040
Lewis Bowick @l-bow.bsky.social · 19/06/2025
Not sure about easy. Freeholder permission needed, and often difficult to pass noise limits due to being close to neighbours' windows. Maintenance at height could be awkward. Feels like flats need fully indoor HPs which duct to outside air
000
Lewis Bowick @l-bow.bsky.social · 19/06/2025
I suppose you can have bypass for the cool night air, then heat exchange to *cool* the fresh air in the afternoon, right? Whereas I have to seal up in the afternoon if I want to keep peak temperatures out, which feels weird!
100
Lewis Bowick @l-bow.bsky.social · 19/06/2025
I suppose I'm basically describing PIV, except timed to run only during cool hours in a heat wave
000
Lewis Bowick @l-bow.bsky.social · 19/06/2025
I'm not sure how much relief extract would provide, pulling air into the rooms from other warm rooms? Having supply at outdoor night time temperatures sounds nicer! I guess some of the extract makeup might come through the trickle vents though
100
Lewis Bowick @l-bow.bsky.social · 19/06/2025
I reckon all it would take would be a fan to duct cool night air into the bedrooms from a quiet side of the house
110
Lewis Bowick @l-bow.bsky.social · 19/06/2025
What I notice in heatwaves is we'd be able to keep cool if we weren't so restricted with ventilation. Security overnight, road noise, curtains to block 5am sunrise (also blocking cool air) and outdoor temps above indoor between midday and 9pm. Precious little opportunity for passive cooling!
230
Lewis Bowick @l-bow.bsky.social · 18/06/2025
Poor bloke should have just followed the handy steps on his EPC. Move out of his downstairs to do underfloor insulation, stick a wind turbine on the back wall and put in flue gas heat recovery to save 2% emissions and get a 150 year payback
000
Lewis Bowick @l-bow.bsky.social · 08/06/2025
Does reducing output on a within-day timescale meaningfully reduce fuel costs? I've been wondering if the renewables which displace French nuclear actually have value. Had it in my head nuclear is virtually all fixed cost
100
Lewis Bowick @l-bow.bsky.social · 05/06/2025
I'd assume there's some crossover point with the design flow temperature of A2W where it becomes more efficient. Like maybe it beats A2A at 35C design but not at 50C
000
Lewis Bowick @l-bow.bsky.social · 05/06/2025
Looking at the datasheets for A2A products, they usually have a tested heating SCOP above 4
110
Lewis Bowick @l-bow.bsky.social · 05/06/2025
Do you have any sources for that? HP efficiency is mainly about the temperature of the condenser, and if anything A2A can probably run cooler than A2W in many cases
100
Lewis Bowick @l-bow.bsky.social · 05/06/2025
I put a heat pump in my 1900 terrace. Works great. Does the same thing the boiler before it did
010
Lewis Bowick @l-bow.bsky.social · 05/06/2025
Very good points!
000
Lewis Bowick @l-bow.bsky.social · 04/06/2025
It's sometimes suggested you could use A2A to displace the bulk of gas heating cheaply, leaving the boiler to pick up periphery rooms on very cold days and hot water. It's a nice idea but you'd have to move the thermostat, which is often hardwired
340
Lewis Bowick @l-bow.bsky.social · 04/06/2025
I mean that if your starting point is electric resistive heating, heat pumps offer a very attractive running cost saving. But if you're starting from gas, there isn't much saving
020
Lewis Bowick @l-bow.bsky.social · 04/06/2025
I think it's more to do with having lots of electric resistive heating, so heat pumps are a slam dunk on running cost savings.
110
Lewis Bowick @l-bow.bsky.social · 04/06/2025
It's not obvious to me how you'd integrate air-to-air with existing central heating. Easier if you've got individually controlled electric heaters in each room, and you just run air-to-air to one or two main rooms, as I think is often the case in Scandinavia
120
Lewis Bowick @l-bow.bsky.social · 04/06/2025
I think there's a lot of electric heating in Scandinavia. It's cheap and easy to put air-to-air in a couple of main living spaces, and leave electric heaters in other rooms and hot water alone. Really strong payback against electric heating too! Replacing gas central heating is harder!
130
Lewis Bowick @l-bow.bsky.social · 29/05/2025
Enter your postcode into the design tool to automatically populate design temp and background noise!
100
Lewis Bowick @l-bow.bsky.social · 29/05/2025
Background noise makes a massive difference. How could that be accounted for in the calc on a simple way without the need for an expensive and slow noise assessment at each site? Some kind of national background noise database?
110
Lewis Bowick @l-bow.bsky.social · 29/05/2025
Yeah passing the noise calc is still pretty difficult for many flats, with neighbour's windows immediately above/below/beside
110
Lewis Bowick @l-bow.bsky.social · 25/05/2025
France is like wow great thanks, let me add this to the rest of my summer Sunday oversupply
010
Lewis Bowick @l-bow.bsky.social · 10/05/2025
Seems disproportionate! Like "we really can't be bothered dealing with this country" pricing
010
Lewis Bowick @l-bow.bsky.social · 10/05/2025
Found out my phone doesn't do eSIMs 😞 But yeah a local physical SIM would be the way for a longer stay.
000
Lewis Bowick @l-bow.bsky.social · 10/05/2025
and no, there's absolutely nothing you can do about it. My travel insurance should cover mountain rescue but maybe not Googling their phone number
100
Lewis Bowick @l-bow.bsky.social · 10/05/2025
I pay £7/mo for 12GB mobile data. Graciously my provider let me use that data for no extra charge in Spain and France. Dipped into the Spanish speaking principality of Andorra for some hiking and all of a sudden they're charging me £9830 per GB!!!
120
Lewis Bowick @l-bow.bsky.social · 10/05/2025
media.tenor.com
a poster for interstellar shows a man crying and says well ill be dammed never thought id see the day
ALT: a poster for interstellar shows a man crying and says well ill be dammed never thought id see the day
020
Lewis Bowick @l-bow.bsky.social · 08/05/2025
Always a tragic pairing to see. #HVAC #IYKYK
010
Lewis Bowick @l-bow.bsky.social · 30/04/2025
Doesn't look like it
000
Lewis Bowick @l-bow.bsky.social · 30/04/2025
But electrification is about to increase the units of consumption. So we can recover the same costs from the current levy rate on the current amount of consumption, meanwhile making the additional consumption levy-free
000
Lewis Bowick @l-bow.bsky.social · 30/04/2025
AFAIK PD is still in the pipeline; this is alongside sorting out PD, not instead of
000
Lewis Bowick @l-bow.bsky.social · 30/04/2025
Consultation launched today on including air-to-air heat pumps in the Boiler Upgrade Scheme! The proposal is for a grant of £1000-2000, which would allow hot water to be provided separately, but would exclude fossil fuel hybrid setups
assets.publishing.service.gov.uk
040